  fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/207 04 rotary switches ac09, 16 and 32 digital code output type description fuji ac series rotary switches offer a wide choice of output codes. they feature sliding au-flashed contacts for high contact reliability. inhibitor and parity check circuits guard against switch malfunctions caused by error signals. with only seven connections to make, these switches are an economical solution to multiposition switching needs. features au-flashed contacts for high contact reliability. the protection of operator section meets the ip65 (iec), so these switches can be used in oil-splash environments, such as on machine tool control panels. a wide choice of output codes fits a broad range of applications. available step angles are 15, 30, and 360?26 (13.85?. real binary code, complementary binary code, and real gray code are available. switches are available with connectors or with lock rings for easy handling. stopper screw positions are user selectable. af90-209, 210, 211 ac16 ac32 ac09 ratings performance volts operational current (a) (resistive load) 50v ac 0.05 5v ac 0.5 25v dc 0.05 5v dc 0.25 rated insulation voltage 60v operating temperature ?0 to +70? humidity 45 to 85%rh (non condensation) service life mechanical 50,000 operations electrical 50,000 operations dielectric between terminals 250v ac, 1 minute strength between terminals and ground 1500v ac, 1 minute insulation between terminals 500m ? or more resistance between terminals and ground 5,000m ? or more degree of protection (operator section) ip65 (iec) type number nomenclature basic type mounting 09: m9 nut 16: m16 adapter 32: adapter (32mm mounting pitch) type of code r: real binary code c: complementary binary code g: real gray code angle of step angle setting position x: 30 0 to 11 w: 360?13 (27.69? 0 to 12 y: 15 0 to 23 z: 360?26 (13.85? 0 to 25 start position available step angle 0 to 11: 30 0 to 12: 360?13 (27.69? 0 to 23: 15 0 to 25: 360?26 (13.85? end position available step angle 0 to 11: 30 0 to 12: 360?13 (27.69? 0 to 23: 15 0 to 25: 360?26 (13.85? with or without lock ring blank: without lock ring 0007: with lock ring 0009: with adhesive lock ring with or without connector blank: 8-terminal, without connector a01: 8-terminal, with right-angle connector a02: 8-termianl, with straight connector b00: 7-terminal, without connector b01: 7-terminal, with right-angle connector b02: 7-terminal, with straight connector with or without stopper screw blank: with stopper screw e: without stopper screw length of shaft (mm) ac09 ac16 ac32 l1: 16 14.5 l2: 18 16.5 l3: 20 18.5 l4: 22 19.5 20.5 note: when shorter action than the maximum range of switch action is used, stopper screws are used. however, stopper screws are not used if the maximum action range is used when either 15 (symbol y) or 360?26 (symbol z) is specified. ac 09 C c z 0 / 25 l1 e a01 / 0007
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/208 m9 nut mounting angle of connector lock ring type step real binary code complementary real gray code binary code 30 without without lock ring ac09-rx / ( ) ac09-cx / ( ) ac09-gx / ( ) connector with lock ring ac09-rx / ( ) /0007 ac09-cx / ( ) /0007 ac09-gx / ( ) /0007 with adhesive lock ring ac09-rx / ( ) /0009 ac09-cx / ( ) /0009 ac09-gx / ( ) /0009 with right without lock ring ac09-rx / ( ) 01 ac09-cx / ( ) 01 ac09-gx / ( ) 01 angle with lock ring ac09-rx / ( ) 01/0007 ac09-cx / ( ) 01/0007 ac09-gx / ( ) 01/0007 connector with adhesive lock ring ac09-rx / ( ) 01/0009 ac09-cx / ( ) 01/0009 ac09-gx / ( ) 01/0009 with without lock ring ac09-rx / ( ) 02 ac09-cx / ( ) 02 ac09-gx / ( ) 02 straight with lock ring ac09-rx / ( ) 02/0007 ac09-cx / ( ) 02/0007 ac09-gx / ( ) 02/0007 connector with adhesive lock ring ac09-rx / ( ) 02/0009 ac09-cx / ( ) 02/0009 ac09-gx / ( ) 02/0009 360?13 without without lock ring ac09-rw / ( ) ac09-cw / ( ) (27.69? connector with lock ring ac09-rw / ( ) /0007 ac09-cw / ( ) /0007 with adhesive lock ring ac09-rw / ( ) /0009 ac09-cw / ( ) /0009 with right without lock ring ac09-rw / ( ) 01 ac09-cw / ( ) 01 angle with lock ring ac09-rw / ( ) 01/0007 ac09-cw / ( ) 01/0007 connector with adhesive lock ring ac09-rw / ( ) 01/0009 ac09-cw / ( ) 01/0009 with without lock ring ac09-rw / ( ) 02 ac09-cw / ( ) 02 straight with lock ring ac09-rw / ( ) 02/0007 ac09-cw / ( ) 02/0007 connector with adhesive lock ring ac09-rw / ( ) 02/0009 ac09-cw / ( ) 02/0009 15 without without lock ring ac09-ry / ( ) ac09-cy / ( ) ac09-gy / ( ) connector with lock ring ac09-ry / ( ) /0007 ac09-cy / ( ) /0007 ac09-gy / ( ) /0007 with adhesive lock ring ac09-ry / ( ) /0009 ac09-cy / ( ) /0009 ac09-gy / ( ) /0009 with right without lock ring ac09-ry / ( ) 01 ac09-cy / ( ) 01 ac09-gy / ( ) 01 angle with lock ring ac09-ry / ( ) 01/0007 ac09-cy / ( ) 01/0007 ac09-gy / ( ) 01/0007 connector with adhesive lock ring ac09-ry / ( ) 01/0009 ac09-cy / ( ) 01/0009 ac09-gy / ( ) 01/0009 with without lock ring ac09-ry / ( ) 02 ac09-cy / ( ) 02 ac09-gy / ( ) 02 straight with lock ring ac09-ry / ( ) 02/0007 ac09-cy / ( ) 02/0007 ac09-gy / ( ) 02/0007 connector with adhesive lock ring ac09-ry / ( ) 02/0009 ac09-cy / ( ) 02/0009 ac09-gy / ( ) 02/0009 360?26 without without lock ring ac09-rz / ( ) ac09-cz / ( ) ac09-gz / ( ) (13.85? connector with lock ring ac09-rz / ( ) /0007 ac09-cz / ( ) /0007 ac09-gz / ( ) /0007 with adhesive lock ring ac09-rz / ( ) /0009 ac09-cz / ( ) /0009 ac09-gz / ( ) /0009 with right without lock ring ac09-rz / ( ) 01 ac09-cz / ( ) 01 ac09-gz / ( ) 01 angle with lock ring ac09-rz / ( ) 01/0007 ac09-cz / ( ) 01/0007 ac09-gz / ( ) 01/0007 connector with adhesive lock ring ac09-rz / ( ) 01/0009 ac09-cz / ( ) 01/0009 ac09-gz / ( ) 01/0009 with without lock ring ac09-rz / ( ) 02 ac09-cz / ( ) 02 ac09-gz / ( ) 02 straight with lock ring ac09-rz / ( ) 02/0007 ac09-cz / ( ) 02/0007 ac09-gz / ( ) 02/0007 connector with adhesive lock ring ac09-rz / ( ) 02/0009 ac09-cz / ( ) 02/0009 ac09-gz / ( ) 02/0009 rotary switches ac09, 16 and 32 * 1 * 2 * 3 notes: * 1 replace the marks by the start and end positions step angle 30 360?13 15 360?26 start and end positions 0 to 11 0 to 12 0 to 23 0 to 25 * 2 replace the ( ) mark by the shaft length code l1: 16mm l2: 18mm l3: 20mm l4: 22mm * 3 replace the mark by the connector blank: 8-terminal, without connector a01: 8-terminal, with right angle connector a02: 8-terminal, with straight connector b00: 7-terminal, without connector b01: 7-terminal, with right angle connector b02: 7-terminal, with straight connector
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/209 04 rotary switches ac09, 16 and 32 notes: * 1 replace the marks by the start and end positions step angle 30 360?13 15 360?26 start and end positions 0 to 11 0 to 12 0 to 23 0 to 25 * 2 replace the mark by the connector blank: 8-terminal, without connector a01: 8-terminal, with right angle connector a02: 8-terminal, with straight connector b00: 7-terminal, without connector b01: 7-terminal, with right angle connector b02: 7-terminal, with straight connector m16 adapter mounting angle of connector type* 1 * 2 step real binary code complementary real gray code binary code 30 without connector ac16-rx / l4 ac16-cx / l4 ac16-gx / l4 with right angle connector ac16-rx / l4 01 ac16-cx / l4 01 ac16-gx / l4 01 with straight connector ac16-rx / l4 02 ac16-cx / l4 02 ac16-gx / l4 02 360?13 without connector ac16-rw / l4 ac16-cw / l4 (27.69? with right angle connector ac16-rw / l4 01 ac16-cw / l4 01 with straight connector ac16-rw / l4 02 ac16-cw / l4 02 15 without connector ac16-ry / l4 ac16-cy / l4 ac16-gy / l4 with right angle connector ac16-ry / l4 01 ac16-cy / l4 01 ac16-gy / l4 01 with straight connector ac16-ry / l4 02 ac16-cy / l4 02 ac16-gy / l4 02 360?26 without connector ac16-rz / l4 ac16-cz / l4 ac16-gz / l4 (13.85? with right angle connector ac16-rz / l4 01 ac16-cz / l4 01 ac16-gz / l4 01 with straight connector ac16-rz / l4 02 ac16-cz / l4 02 ac16-gz / l4 02 notes: * 1 replace the marks by the start and end positions step angle 30 360?13 15 360?26 start and end positions 0 to 11 0 to 12 0 to 23 0 to 25 * 3 replace the mark by the connector blank: 8-terminal, without connector a01: 8-terminal, with right angle connector a02: 8-terminal, with straight connector b00: 7-terminal, without connector b01: 7-terminal, with right angle connector b02: 7-terminal, with straight connector adaptor mounting (32mm mounting pitch) angle of connector type* 1 * 2 * 3 step real binary code complementary real gray code binary code 30 without connector ac32-rx / ( ) ac32-cx / ( ) ac32-gx / ( ) with right angle connector ac32-rx / ( ) 01 ac32-cx / ( ) 01 ac32-gx / ( ) 01 with straight connector ac32-rx / ( ) 02 ac32-cx / ( ) 02 ac32-gx / ( ) 02 360?13 without connector ac32-rw / ( ) ac32-cw / ( ) (27.69? with right angle connector ac32-rw / ( ) 01 ac32-cw / ( ) 01 with straight connector ac32-rw / ( ) 02 ac32-cw / ( ) 02 15 without connector ac32-ry / ( ) ac32-cy / ( ) ac32-gy / ( ) with right angle connector ac32-ry / ( ) 01 ac32-cy / ( ) 01 ac32-gy / ( ) 01 with straight connector ac32-ry / ( ) 02 ac32-cy / ( ) 02 ac32-gy / ( ) 02 360?26 without connector ac32-rz / ( ) ac32-cz / ( ) ac32-gz / ( ) (13.85? with right angle connector ac32-rz / ( ) 01 ac32-cz / ( ) 01 ac32-gz / ( ) 01 with straight connector ac32-rz / ( ) 02 ac32-cz / ( ) 02 ac32-gz / ( ) 02 * 2 replace the ( ) mark by the shaft length l1: 14.5mm l2: 16.5mm l3: 18.5mm l4: 20.5mm
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/210 rotary switches ac09, 16 and 32 24-position r: real binary code c: complementary binary code 12-position r: real binary code g: real gray code c: complementary binary code g: real gray code terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 a1 f2 b4 e8 c16 g inh dc 26-position r: real binary code terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 a1 f2 b4 e8 c16 g inh dc terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 aa fb bc ed ce gp dc terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 aa fb bc ed ce gp dc terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 a1 f2 b4 e8 c16 g inh dc terminal bit setting position no. no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 a1 f2 b4 e8 c16 g inh dc terminal bit setting position no. no. 01234567891011 aa fb bc ed cp g dc c: complementary binary code g: real gray code terminal bit setting position no. no. 01234567891011 a1 f2 b4 e8 cp g inh dc terminal bit setting position no. no. 01234567891011 a1 f2 b4 e8 cp g inh dc inh : inhibit terminal p : parity check terminal c : common terminal : turned on 13-position r: real binary code c: complementary binary code terminal bit setting position no. no. 0123456789101112 a1 f2 b4 e8 cp g inh dc terminal bit setting position no. no. 0123456789101112 a1 f2 b4 e8 cp g inh dc
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/211 04 rotary switches ac 09, 16 and 32 dimensions, mm ac09 ac09 (with connector) mass: 47g panel cutting panel cutting ac16 ac32 panel cutting shaft length l1 l2 l3 l4 * 14.5 16.5 18.5 20.5 mass (g) 47 48 49 50 panel cutting 25.5 * l 8 panel thickness max. 4 m9p=0.75 ? ?.1 +0.3 ? 2.54 17.78 22 31 30 28 20 22 15.8 8-terminal abcddefg panel thickness max. 4 m9p=0.75 6 40 25.5 8 * l 32 30.5 23.4 right-angle connector straight connector 9.1 +0.3 0 17.78 22 2.54 31 30 28 20 22 15.8 8-terminal abcddefg 9.1 2.7 +0.3 0 in case of using lock ring (ac09- /0007) panel thickness 1.2 to 3.2 m16p=1 28 19.5 11 panel thickness max. 4 6 20 16.1 +0.3 0 2.54 17.78 22 31 30 28 20 22 15.8 8-terminal abcddefg m9p=0.75 27 * l 6.4 panel thickness max. 4 6 20 32 0.2 17 m2.3 (for flat head screw) 28 20 22 15.8 2.54 17.78 22 30 31 m2.3 6 38 32 8-terminal abcddefg shaft length l1 l2 l3 l4 * 16 18 20 22 mass (g) without connector 41 42 43 44 with connector 42 43 44 45 length of lead wire (m) type mass (g) 0.5 acx011-805 11 1.0 (standard) acx011-810 19 2.0 acx011-820 33 614 l 20.5 type mass (g) lock ring (inserted) acx001 2 lock ring (sealed) acx001a 5 acx001 af91-675 accessories lead wire with connector (8-terminal) af91-710 l : 0.5, 1.0, 2.0m lock ring ?6 ?8 4.7 ?.1 1 1.2 8 1.9 ?.1 ?0 1.5 1 acx001a
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/212 notes on use 1. connecting wires note the following points when soldering: the power of the soldering iron must not be over 30w. use solder with resin flux core. complete soldering within 5 seconds if using a 30w soldering iron, or within 10 seconds if using a 20w soldering iron. 2. note on the case linkage rotary switches ac09, 16 and 32 3. number of stopper screws shipped ac09 and ac32 step angle: 30?(symbol x) positions 0/11 (0 to 11): one screw. user-selectable start and stop positions: two screws (one for start position, one for end position). step angle: 15?(symbol y) positions 0/22 (0 to 22): one screw. user-selectable start and stop positions: two screws (one for start position, one for end position). step angle: 360?26 (symbol z) positions 0/24 (0 to 24): one screw. user-selectable start and stop positions: two screws (one for start position, one for end position). ac16 customers can specify the stopper screw positions. the switch is then shipped with stopper screws already in the specified positions. 4. stopper screw positions insert stopper screws into the switch body holes marked with letters, as shown in the insertion example on the right. these tables below show that the start position stopper screw is inserted in the hole on the left of the position setting and the end positions stopper screw is inserted in the hole on the right. do not disconnect this case linkage. switch bod y stopper screw holes (24) stopper screw holes (26) if step angle x (30 ) or y (15 ) is specified. if step angle w (360 /13) or z (360 /26) is specified. g h i j k l m n o p q r s t u v w x a b c d e f g h i j k l m n o p q r s t u v w x y z a b c d e f 5. installing a stopper screw the maximum tightening torque for a stopper screw is 0.1n?. screw the stopper screw into position until it hits the body frame rib. do not overtighten the screw. stopper screw stopper screw frame rib ac09 pass the switch body through the hole from the back of the panel, and secure it by tightening the hexagonal nut with a flat washer and a toothed lock washer. the recommended tightening torque for the hexagonal nut is 1.5 to 2n?. insert the lock ring (acx001) between the panel and the flat washer, and the adhesive lock ring (acx001a) between the switch body and the panel. installation ac16 pass the switch body with a bezel through the hole from the back of the panel, and secure it with a 16 mounting nut. the recommended tightening torque for the nut is 0.6 to 1n?. ac32 pass the switch body through the hole from the back of the panel, and secure it with two flat head screws from the face of the panel. the recommended tightening torque for the flat head screws is 0.3 to 0.5n?. switch body o ring panel flat washer toothed look washer m9 hexagonal nut packing panel panel 16 mounting nut m2.3 flat head screw
fuji electric fa components & systems co., ltd./d & c catalog information subject to change without notice 04/213 04 rotary switches ac 09, 16 and 32 setting stopper screw position a c 01234567891011 eg i k o m qu s w a start position setting end position setting range of switch action start side stopper screw position end side stopper screw position notes: 1. if the range of action is designated as 0/24 (0 to 24), insert a stopper screw in hole a only. 2. if the range of action is designated as 0/25 (0 to 25), no stopper screws are inserted (symbol ? is e). ? if symbol ? (step angle) is z-----type ac09-cz0/7l1: insert the start side stopper screw in hole a and the end side screw in hole j. ? if symbol ? (step angle) is y-----type ac09-cy0/7l1: insert the start side stopper screw in hole a and the end side screw in hole j. start side end side setting stopper screw position a b c 01234567891011121314151617181920212223 c de d f ef gh g i h j j i kl kl o n m m np o p qr qr stuv stuv w x x w ab start position setting end position setting range of switch action start side stopper screw position end side stopper screw position notes: 1. if the range of action is designated as 0/22 (0 to 22), insert a stopper screw into hole a only. 2. if the range of action is designated as 0/23 (0 to 23), no stopper screws are inserted (symbol ? is e). ? if symbol ? (step angle) is x-----type ac09-cx0/7l1: insert the start side stopper screw in hole a and the end side screw in hole q. start side end side setting stopper screw position a b c 012345678910111213141516171819202122232425 c de d f ef gh g i h j j i kl kl o n m m np o p qr qr stuv stuv w xyz xyz w ab start position setting end position setting range of switch action start side stopper screw position end side stopper screw position setting stopper screw position a c 01234567891011 eg i k o m qu s w a start position setting end position setting range of switch action start side stopper screw position end side stopper screw position ac09-c  0/7l1  insertion example 1 ? step angle x: 30? w: 360?13, y: 15? z: 360?26 ? start position setting: 0 ? with a stopper screw blank: with stopper screw e: no stopper screw ? end position setting: 7 ac09-rx2/11 step angle start position setting end position setting insertion example 2 ? if symbol ? (step angle) is w-----type ac09-cw0/7l1: insert the start side stopper screw in hole a and the end side screw in hole q. setting stopper screw position a c 0123456789101112 eg i k o m qu s w ya start position setting end position setting range of switch action start side stopper screw position end side stopper screw position


▲Up To Search▲   

 
Price & Availability of AC09-RW012L3B01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X